Chapter 5 5 ft high mse wall and barrier study design of. Chapter 6 10 ft high mse wall and barrier study design. Todays mse contractors dont want to solve jigsaw puzzles. Ss840 mechanically stabilized earth mse wallsbe advised ss840 dated 41920 is included in its entirety at the end of this document for reference only.
The answer to each of these should be yes unless plans, specifications or specific approval has been given otherwise. Tricons engineering excellence translates to simple and efficient installation procedures requiring no tools. Monitoring and repair of distressed mechanically stabilized earth wall. After the cast pieces were stripped from their molds they were placed in a racking system facing each panel to the south. This is a standard special provision that revises or modifies cdots. These walls perform well, and tens of millions of square feet of. The wall panel attached to the instrumented strips was instrumented with three concrete strain gages to capture nor mal strains in the panel induced from impact loads transmit ted into the mse wall through the soil and generated from direct contact of the barriera coping section with the top of the wall panel. They are inserted between panels to help provide the proper spacing. Sp150404 new special provisions for aesthetic treatment of.
Here are a few illustrations of the most common types of failure. By choosing to continue, you agree to the terms in our privacy policy. Mse walls and retained soil walls precast concrete wall. A wall consisting of a volume of select backfill with tensile earth reinforcement elements distributed throughout. Section 504 of the standard specifications is hereby revised for this project to include the following. The coping is used at the top of the wall panels to provide an aesthetic finish to. Hybrid walls will be permitted, unless otherwise stated by the designer in the general notes for the mse wall worksheets. How uretek repairs mechanically stabilized earth mse walls by robert armstead.
These top wall products deliver reinforced stability as well as aesthetic appeal to a variety of projects. Mse backfill was found in storm sewer system at base of wall. Mechanically stabilized earth wall abutments for bridge. Geotechnical engineer key person for the mse segmental wall design consultant.
Storm sewer system was videoed and a break in the system identified, remaining system was in acceptable shape plan for repair included removal and replacement of pavement, backfill of void identified, repair of storm sewer. Outline of mse wall panel extended cap such that mse panels are installed below extended cap and within a 6 x 9 notch. The wall surface can be placed vertically or in a tiered setback configuration. History wall built in the mid 90s supports the wb main lanes of us 290 us 290 in this location is 4 lane with an adt of approximately 80,000. There are many difference scenarios where mse or retaining walls are present. Retaining walls texas department of transportation. The mse wall supplier may fabricate top of wall panels greater than 50 ft. Importance of water management civil site improvements can create avenues for water to enter the wall system, and proper water management is needed for all mse walls. The overall global stability of an mse wall system is the responsibility of the engineer who selects this type of wall for inclusion into the plans. Inspectors manual for mechanically stabilized earth walls. Gec 11 design and construction of mechanically stabilized. The rw mse dd design data is a 20 standard sheet in the proprietary retaining walls section.
Many of the chips and cracks are caused by poor handling. Ssls systems and services address every application of mse wall types known today with a wide variety of finishes mseplus by ssl has become the system of choice among north americas top highway contractors. Mse wall panels interface with abutment thru a 6 x 9 notch in cap and wingwall. This is the result of improved understanding of the systems and design methodologies, but primarily because of their. Mse wall, the loss of backfill material through the joints of the. Nilexs mse panel systems provide a structurally dependable solution for a. In previous years, there were special provisions in the contract that detailed the construction and design. The stability of the wall system is derived from the interaction between the backfill and soil reinforcements, involving friction and tension. Permanent mse walls use a precast concrete panel as a facing element. Wall facing panel wall facing panels are used to hold th e soil in position at the face of the wall. Top of mse wall panels must be totally concealed within height of the precast coping element. Mse wall mechanically stabilized earth retaining wall. If needed, the mse wall supplier may fabricate top of wall panels greater than 50 square feet but less than 75 square feet, to accommodate top of wall profile. No density tests 4 passes with a vibratory roller and 1.
Proper spacing keeps the panels from having point contact and spalling the concrete. Nilex mse panel systems can be designed to fit the architectural, structural, and budgetary needs of any retaining wall project. The fullheight wall panel below the point of impact on the barrier was instrumented with i ve concrete strain gages to capture normal strains in the panel induced from impact loads transmitted into the mse wall and generated from direct contact of the barriera coping section with the top of the wall panel. Next, a finiteelement computer model sap2000 was created to independently predict if similar cracks would form in a panel given various restraint conditions. The preferred standard panel size for straight wall segments is 10. Pavement cracks adjacent to walls are common, as mse walls often move to fully engage the reinforcing.
Design manual mechanically stabilized earth mse chapter. Mse wall corrosion monitoring kit installation guide. Missouri university of science and technology scholars mine. The design of these walls is unique because limited rightofway often forces the length of the reinforcing strips to be shorter than normally used. Standard specifications for road and bridge construction. Spacers wall panel spacers are typically ribbed elastomeric or polymeric pads. Successful wall construction requires a basic understanding of mse wall con struction and. This mechanically stabilized earth walls mse and reinforced soil slopes rss, design and construction guidelines manual which is an update of the current fhwa nhi00043, has evolved from the following aashto and fhwa references. A third party performed a photospectrometer color measurement check on each panel before the panel was approved for shipping. The wall system consists of the original ground, concrete leveling pad, wall facing panels, coping, soil reinforcement, select backfill and any loads and surcharges. Separation of the corner of a precast panel as a result of structural cracking. Faddis is familiar with all of the approved systems and has experience casting the various coping or parapets. Basic failure modes in addition to these basic modes of failure mse walls, especially tall ones, may fail globally. Where an obstruction projects through the mse wall panel, the obstruction should also be shown in an isolated section and elevation view.
A retaining wall so designated by description, with a design service life of 3 years. All of these items have an affect on the performance of the mse wall and are taken into account in the stability analysis. Wallreinforcement connection this is where the soil reinforcement ties into the wall facing panel. Mechanically stabilized earth wall abutments for bridge support introduction using mse structures as direct bridge abutments would be a significant simplification in the design and construction of current bridge abutment systems and would lead to faster construction of highway bridge infrastructures. Mse walls have become a staple to both commercial and residential developm ent over the last 10 to 20 years. Loss of backfill in mechanically stabilized earth retaining walls. Wall reinforcement connection this is where the soil reinforcement ties into the wall facing panel. All costs associated with integrally colored concrete for mse retaining wall precast concrete panels, furnishing and placing form liners and rustication, constructing mockup panel s, and all labor, equipment and incidentals needed to complete the described work shall be considered incidental to the mechanically stabilized earth retaining wall. Mechanically stabilized earth mse walls in accordance with this sts and the wall.
For mse embankments, bridge abutments, cut walls and other applications, our patented connection systems streamline the installation process, saving time and money. Structure magazine crack control measures for tiltup. Faddis is familiar with all of the approved systems and has experience casting. Chapter 6 10 ft high mse wall and barrier study design of. Nebraska transportation center report sprp1 09 p320 final report inspectors manual for mechanically stabilized earth walls this report was funded in part through grants from the federal highway administration and federal transit administration, u.
If a crack was predicted to initiate, the model would further help indicate where the first crack was likely to appear as well as its direction of travel through the panel. This paper describes a successful failure analysis to determine the causes of loss of backfill sand from a mechanically stabilized earth mse wall, and cracks on the concrete approach slabs on. Damaged panels or srw units with excessive discoloration, chips or cracks as determined by the engineer will be rejected. Products ssl offers a variety of mse systems for a range of applications. Repair of a 30 tall mse wall lessons learned presented by. The mse wall footprint area needs to be prepared in the leveling pad, soil reinforcement, and select granular backfill areas. These walls perform well, and tens of millions of square feet of mse wall are currently in service. The proven mechanical connection provided on nilexs wall systems assures longterm durability and structural integrity. Wall facing panel wall facing panels are used to hold the soil in position at the face of the wall. Chapter 5 5 ft high mse wall and barrier study design. The panels are typically concrete but they can be metal, wood, block, mesh or other material. For more than 40 years, mechanically stabilized earth mse retaining walls have been used to reinforce earthen structures, such as those found in constructing highways and roads, dams, bridge abutments, seawalls, dikes, golf courses, and other grade separation applications. The mse panel retaining wall system performs extremely well in a multitude of conditions, and particularly well in seismic zones, due to the builtin flexibility of the system, which allows for some movement without distressing the structure or causing cracks. The builtin flexibility allows for certain movement without causing distress to the structure or producing cracks.
Provide mse panel wall designs sealed by a design engineer licensed in the state of north carolina and employed or contracted by the mse wall vendor. Provide mse panel wall designs sealed by a design engineer licensed in the state of. Tiltup concrete construction incorporates concrete wall panels that are formed, cast and cured on a ground supported slab at the building site and then tilted into place, one large panel at a time. Mse walls are defined as large panel retaining wall systems that use metallicgeosynthetic mesh or strips in the soil backfill material behind a concrete panel wall facing to limit backfill. Bridge director, indot manager, indot office of geotechnical services. Mechanically stabilized earth wall abutments for bridge support introduction using mse structures as direct bridge abutments would be a significant simplification in the design and construction of current bridge abutment systems and would lead to faster construction of highway bridge. Mechanically stabilized earth mse wall systems are retaining wall structures that function as gravity walls. Water must be controlled such that entry into the mse wall system is minimized.
Mse panel retaining walls can also tolerate a specific amount of settlement that makes it a desirable solution even in relatively poor subsoil conditions. Pdf inspection and risk assessment of mechanically stabilized. Mse walls are wid ely u sed in site d evelopm en t, prim arily due to their low co st wh en co m pared with co nv en tional retain ing stru ctures. Widening of existing highways often results in new mechanically stabilized earth mse walls being placed in front of existing stable walls. Conceal the top of mse wall panels within the height of the precast coping element. Each panel is connected to its reinforcement in the backfill by means of coil loop connectors and threaded coil rods, allowing for appropriate relative movement between the.
Design manual mechanically stabilized earth mse chapter 200. Special or oversized panels shall be detailed in the shop drawings. Mechanically stabilized embankment mse for retaining walls on most state highway projects, the typical wall is constructed of a precast panel facing and granular soils reinforced with linear reinforcements of metal strips, metal grids, or hdpe grids. All costs associated with integrally colored concrete for mse retaining wall precast concrete panels, furnishing and placing form liners and rustication, constructing mockup panels, and all labor, equipment and incidentals needed to complete the described work shall be considered incidental to the mechanically stabilized earth retaining wall. The greenwall system is a fullyfunctional mse wall with facing panels that accommodate soil, root systems, and drip irrigation for sustaining vegetation. No density tests 4 passes with a vibratory roller and 1 pass with the same roller in the static. Select granular fill structure backfill, type 3 excludes no.
Mechanically stabilized earth wall abutments for bridge support. Jul 01, 2010 use in projects having concrete panel facing mse walls. The production team tried to schedule pouring and stripping from the mold at the same time every day. Ssls systems and services address every application of mse wall types known today with a wide variety of finishes. Wall panels come in many shapes and sizes see figure 4, some panel finishes and shapes for a few of the most common shapes. This research addressed such walls placed in a confined. That is, the entire soil mass behind the wall may fail due to a zone of. Design mse walls in accordance with the plans, aashto lrfd bridge design. Design and construction guidelines for mse walls with independent full height facing panels by naser abuhejleh. Color variation on front face of panel due to excess form oil or other reasons. Mechanically stabilized earth mse walls in accordance with this sts and the wall manufacturers recommendations, and in conformance with the lines, grades, designs, and dimensions shown in the plans or established by the resident construction engineer rce. Mse wall failures visavis the lack of geotechnical filters.
The individual wall panels are erected around the buildings perimeter, separated by vertical joints. Over the last few years, we have expanded the number and variety of mse top wall products available. Loss of backfill in mechanically stabilized earth retaining walls mechanically stabilized earth mse retaining walls have been used extensively by the texas department of transportation txdot since the late 1970s. Pdf inspection and risk assessment of mechanically. The features and advantages of the mse iff wall in relation to other conventional and mse wall systems are described.
Mse walls have been constructed in the state of ohio for over 25 years. Mechanically stabilized earth walls concrete panel facing october 28, 2014 1. Wall facing panel wall facing panels or panels are used to hold the soil in position at the face of the wall. Spmi offers a full array of precast top wall elements. Review the section 840 in the mop for mechanically stabilized earth mse walls. Mse wall suppliers are only responsible for the internal stability of their walls. The proposed mse iff wall system is adequate for all field conditions found suitable for the use of mse walls. Mechanically stabilized earth mse wall inspectors handbook. Indot check list for mse wall construction the following is a general checklist to follow when constructing a mechanically stabilized earth wall mse wall. A mechanically stabilized earth mse retaining wall is a composite structure consisting of alternating layers of compacted backfill and soil reinforcement elements, fixed to a wall facing. Use in projects having concrete panel facing mse walls. Speed fabcrete places colored concrete in mse wall forms.
1274 301 1206 202 331 313 1405 63 1392 295 795 262 96 903 232 164 414 1241 289 335 406 1305 393 773 2 618 884 1319 1095 774 1452 1187 1417 199 681 885 161 1348 169 117 372 760 107 1192